​North-Wright Air has retained Stantec Architecture Ltd. (Stantec) to undertake geotechnical and structural engineering services for a new Hanger Building in Norman Wells. Geotechnical recommendations forr the building foundation and slab design will be required.

The geotechnical investigation will consist of completing 5 boreholes with a track mounted drill rig to approximately 6 m depth. Geotechnical personnel will coordinate and supervise the drilling operations. The boreholes will be logged based on visual, physical, and textural properties observed in the field. Representative grab samples will be collected directly off of the augers during the field drilling program. The groundwater level within the boreholes will be recorded immediately after drilling is completed. A thermistor will be installed in one of the boreholes for ground temperature monitoring purposes and a standpipe monitoring well will be installed  in another for ground water level monitoring. The boreholes will be backfilled with a combination of auger cuttings, and bentonite. Excess auger cuttings will be left at the borehole locations. The borehole coordinates will be recorded using a handheld GPS.


No drilling fluids and/or water sources are required for the drilling

Documents

Uploaded On or After
Uploaded On or Before
Displaying 1 - 12 of 12
2. Initial/Renewal Application
Application and Related Docs
Document Received/Sent Uploaded
S24S-002 - Draft Land Use Permit Conditions - Apr23_24.pdf (411.88 KB)
S24S-002 - NWHanger Geotechnical Investigation - Engagement Plan - Version 2.0 - Apr1_24.pdf (170.4 KB)
S24S-002 - NWHanger Geotechnical Investigation - Engagement Plan - Version 3.0 - Apr16_24.pdf (155.23 KB)
S24S-002 - NWHanger Geotechnical Investigation - Security Estimate - Version 1.0 - Apr1_24.pdf (122.74 KB)
S24S-002 - NWHanger Geotechnical Investigation - Updated Security Estimate - Version 2.0 - Apr9_24.pdf (119.42 KB)
S24S-002 - NWHanger Geotechnical Investigation - LUP Application Form - Version 2.0 - Apr1_24.pdf (532.01 KB)
S24S-002 - NWHanger Geotechnical Investigation - Application Fee - Mar 13_24.pdf (86.21 KB)
S24S-002 - NWHangar Geotechnical Investigation - LUP Application Form - Feb21_24pdf.pdf (483.02 KB)
S24S-002 - NWHangar Geotechnical Investigation - Spill Contingency Plan - Version 1.0 - Feb21_24.pdf (1.29 MB)
S24S-002 - NWHangar Geotechnical Investigation - Waste Management Plan - Version 1.0 - Feb21_24.pdf (107.12 KB)
S24S-002 - NWHanger Geotechnical Investigation - Engagement Plan - Version 1.0 - Feb21_24.pdf (785.52 KB)
Withdrawal - Return - Denial
Document Received/Sent Uploaded
S24S-002 - NWHanger Geotechnical Investigation - Incomplete Letter - Mar15_24.pdf (400.6 KB)